How well can an electric valve actuator withstand dust, rain, flooding, or immersion? The answer depends partly on its IP rating, enclosure design, cable entries, seals, and installation conditions.

IP67 and IP68 actuators are both dust-tight, but their water-protection requirements differ. IP67 addresses temporary immersion under standardized conditions. IP68 covers immersion under conditions declared by the manufacturer. However, IP68 does not automatically confirm unlimited underwater operation.

For industrial buyers, the correct choice depends on actual exposure, installation position, operating mode, required service life, and available test documentation. This guide compares IP67 and IP68 electric valve actuators and explains what purchasers should verify before ordering.

Understanding IP Ratings: Basics for Electric Valve Actuators

What Is an IP Rating? Ingress Protection Explained

An IP rating classifies how effectively an electrical enclosure protects internal components against contact, solid foreign objects, and water ingress. The rating system is defined by IEC 60529.

For an electric valve actuator, the enclosure protects components such as the motor, gears, limit switches, sensors, terminals, and control electronics. If dust or water enters the housing, it may cause corrosion, electrical faults, inaccurate positioning, or mechanical failure.

An IP rating is therefore an important selection criterion, but it is not a complete measure of actuator durability. It does not automatically confirm resistance to corrosion, chemicals, salt spray, UV exposure, vibration, impact, steam, or explosive atmospheres.

Structure of IP Ratings: What the Two Digits Mean

An IP code normally contains two characteristic digits:

  • First digit: Protection against access to hazardous parts and solid foreign objects.

  • Second digit: Protection against the harmful effects of water ingress.

For IP67 and IP68:

  • The first digit 6 indicates a dust-tight enclosure.

  • The second digit 7 indicates protection against temporary immersion under specified test conditions.

  • The second digit 8 indicates protection against immersion under conditions agreed between the manufacturer and user.

The immersion depth, duration, enclosure condition, and operating state must therefore be confirmed instead of assuming that every IP68 actuator provides identical protection.

How IP Ratings Apply to Electric Valve Actuators

Electric valve actuators may operate in dusty plants, outdoor pipelines, wastewater facilities, irrigation systems, marine environments, or underground installations. Each environment creates different ingress risks.

Dust may enter through damaged seals, cable glands, covers, or shaft interfaces. Water may reach the actuator through rain, condensation, washdown, flooding, or immersion. Cable entries and terminal compartments are often as important as the main enclosure.

Industrial buyers should verify whether the stated IP rating applies to:

  • The complete assembled actuator

  • The terminal compartment and cable entries

  • The local control panel or display

  • The actuator in its specified mounting position

  • The output shaft and valve interface

  • Stationary equipment or equipment operating during exposure

An actuator enclosure may have a high IP rating, but incorrect cable glands or installation practices can reduce the protection of the completed assembly.

Note: An IP rating describes enclosure protection under defined test conditions. It does not independently guarantee corrosion resistance, underwater functionality, or suitability for every outdoor environment.

Electric Valve Actuator

Detailed Explanation of IP67 Rating for Electric Valve Actuators

Protection Against Solids: Dust-Tight Classification

The first digit in IP67 is 6, the highest dust-protection category within the standard IP code. It indicates that the enclosure is dust-tight under the applicable test requirements.

This level of protection can benefit actuators installed in environments containing soil, powder, sand, fibers, or airborne industrial particles. Preventing dust ingress helps protect electrical terminals, control components, gears, and position-feedback devices.

However, maintaining this protection depends on correct assembly. Covers, O-rings, shaft seals, cable glands, and unused cable openings must all be properly installed and maintained.

Water Protection: Temporary Immersion

The second digit 7 addresses temporary immersion in water under standardized conditions. IP67 is commonly associated with immersion for 30 minutes, with the enclosure positioned according to the applicable test requirements.

This rating can be appropriate where an actuator may experience:

  • Heavy rain

  • Water splashes

  • Accidental flooding

  • Brief immersion

  • Outdoor moisture

  • Temporary water accumulation

IP67 should not be interpreted as approval for permanent underwater installation. It also does not automatically cover high-pressure cleaning, hot-water washdown, saltwater corrosion, or operation while submerged.

Typical Environments and Applications for IP67 Electric Valve Actuators

IP67 electric valve actuators may suit above-ground and outdoor installations where temporary water exposure is possible but continuous immersion is not part of normal operation.

Potential applications include:

  • Outdoor water-treatment pipelines

  • Irrigation and drainage systems

  • Industrial utility lines

  • Dusty processing facilities

  • Rain-exposed valve stations

  • Flood-prone installations with temporary exposure

  • Marine-side equipment exposed to spray rather than permanent immersion

Application suitability still depends on temperature, corrosion conditions, valve torque, operating frequency, power supply, control requirements, and installation orientation.

Limitations and Procurement Considerations for IP67

Before purchasing an IP67 actuator, buyers should confirm the limits of the rating.

Important questions include:

  • Was the complete actuator assembly tested?

  • What mounting position was used during testing?

  • Were cable glands and connectors included?

  • Was the actuator energized or operating during the test?

  • Does the rating apply after manual override operation?

  • Are external metal parts suitable for the expected corrosion conditions?

  • What maintenance is required to preserve enclosure protection?

IP67 can provide appropriate protection for many industrial installations. However, it should not be selected for continuous immersion unless the manufacturer provides additional verified suitability data.

Detailed Explanation of IP68 Rating for Electric Valve Actuators

Protection Against Solids: Dust-Tight Classification

Like IP67, IP68 begins with the digit 6. Both classifications therefore provide the same dust-tight category under the IP code.

The difference lies in water protection, not dust protection. An IP68 actuator is not inherently more dust-resistant than an IP67 actuator.

For dusty applications, buyers should still examine:

  • Enclosure joints

  • Shaft sealing

  • Terminal covers

  • Cable-gland specifications

  • Breather or drainage devices

  • Maintenance access points

The complete installed system must preserve the rated sealing performance.

Water Protection: Manufacturer-Declared Immersion Conditions

The second digit 8 indicates protection against immersion under conditions specified through agreement between the manufacturer and user. These conditions must be more demanding than those used for IPX7, but IEC 60529 does not assign one universal depth and duration to every IP68 product.

One IP68 actuator may be tested at a particular depth for several hours. Another may be tested under different pressure, duration, and mounting conditions. Both can carry an IP68 rating while having different application limits.

Buyers should therefore request the exact:

  • Tested immersion depth

  • Test duration

  • Water temperature

  • Mounting orientation

  • Actuator operating state

  • Cable-entry configuration

  • Acceptance criteria

  • Applicable test standard and report

IP68 should be treated as a defined test result rather than a general promise of unlimited underwater service.

Typical Environments and Applications for IP68 Electric Valve Actuators

IP68 may be considered when an actuator faces extended immersion or installation below the expected water level.

Potential applications include:

  • Submerged water-control valves

  • Underground chambers exposed to flooding

  • Dam and reservoir systems

  • Irrigation infrastructure

  • Water and wastewater installations

  • Marine-related valve systems

  • Flood-control equipment

However, an IP68 rating alone does not confirm resistance to seawater, chemicals, sewage, sediment, biological growth, or external water pressure over the required service life. These conditions require additional material and application review.

Why Manufacturer-Specified Conditions Matter

Industrial buyers should avoid treating every IP68 actuator as equivalent. The practical protection level depends on the manufacturer’s declared test conditions and the scope of the tested configuration.

The following details should be confirmed:

  • Whether immersion is temporary, extended, or continuous

  • Maximum installation depth

  • Permitted immersion duration

  • Whether the actuator can operate while submerged

  • Whether repeated immersion is covered

  • Whether freshwater, wastewater, or saltwater was considered

  • Whether connectors and cable glands maintain the same rating

  • Whether the rating applies throughout the expected service life

Summary Table: IP68 Variables to Confirm

Parameter

Information Required from the Supplier

Immersion depth

Exact tested or approved depth

Immersion duration

Test period and permitted service duration

Operating condition

Energized, de-energized, stationary, or moving

Mounting position

Approved installation orientations

Water environment

Freshwater, wastewater, saltwater, or other fluids

Cable entries

Required glands, connectors, plugs, and sealing methods

Test basis

Applicable standard and test-report reference

Maintenance

Seal inspection and replacement requirements

Key Differences Between IP67 and IP68 Electric Valve Actuators

Direct Comparison of IP67 and IP68

Comparison Point

IP67 Electric Valve Actuator

IP68 Electric Valve Actuator

Dust protection

Dust-tight

Dust-tight

Water protection

Temporary immersion under standardized conditions

Immersion under manufacturer-declared conditions

Standard depth and duration

Commonly associated with temporary immersion for 30 minutes

No single universal depth or duration

Continuous underwater use

Not covered by IP67 alone

Must be specifically confirmed

Operation while submerged

Not automatically covered

Not automatically covered

Typical use

Outdoor exposure, temporary flooding, brief immersion

Extended immersion or specially defined submerged applications

Procurement focus

Confirm complete assembly and temporary-immersion limits

Confirm depth, duration, operating state, and test documentation

Cost consideration

Often sufficient for demanding outdoor installations

May involve additional sealing, materials, testing, and cost

Comparison of Immersion Conditions

The essential difference is how water exposure is defined.

IP67 follows a standardized temporary-immersion test. It is suitable where immersion is accidental, brief, or infrequent. IP68 uses conditions declared for the specific product. The buyer must confirm those conditions against the project requirements.

IP68 should not be selected only because its number is higher. If an actuator is exposed to high-pressure washdown but never submerged, another water-protection classification may be more relevant.

Stationary Testing Versus Operation During Immersion

An IP rating does not automatically prove that an electric valve actuator can cycle while underwater. Shaft movement, manual override operation, thermal changes, and internal pressure variations may affect sealing performance.

For submerged operation, buyers should request written confirmation covering:

  • Whether the actuator was operating during testing

  • The number of operating cycles completed

  • The valve load or output torque applied

  • The approved duty cycle

  • The permitted depth and duration

  • Post-test electrical and functional checks

A general IP68 statement should not replace application-specific operating confirmation.

Cost and Total Ownership Considerations

IP68 actuators may require more specialized seals, cable systems, enclosure construction, testing, and corrosion protection. This can increase the initial purchase price.

However, price should not be evaluated independently from installation risk. An under-specified actuator can cause valve failure, process interruption, replacement costs, or difficult underwater maintenance.

An over-specified product may also add unnecessary cost. The most economical choice is the protection level that matches the actual exposure and documented operating requirements.

Impact on Actuator Selection

Use IP67 when the primary risks are dust, rain, splashing, and temporary immersion. Consider IP68 when the actuator will face immersion beyond IP67 test conditions.

In either case, buyers should also evaluate:

  • Required actuator torque

  • Valve type and operating angle

  • Power supply and control signal

  • Open-close or modulating duty

  • Ambient and fluid temperatures

  • Corrosion and chemical exposure

  • Manual override requirements

  • Feedback and communication options

  • Installation space and mounting position

  • Maintenance accessibility

Tip: Select the actuator from the complete operating profile. IP protection is important, but it cannot replace torque, duty-cycle, material, control, and environmental checks.

Choosing the Right IP Rating for Your Electric Valve Actuator

Assess the Installation and Operating Environment

Start by identifying how the actuator will be exposed to dust and water. Consider whether it will operate indoors or outdoors and face rain, condensation, pressure cleaning, temporary flooding, or continuous immersion. Buyers should also confirm the maximum water depth, exposure duration, ambient temperature, chemical or salt contact, UV exposure, and mounting orientation. Define whether the actuator must only survive water exposure or remain powered, cycle repeatedly, or support manual operation while submerged. These conditions help determine whether IP67, IP68, or another protection level is appropriate.

Compare Costs and Verify Supplier Documentation

The highest IP rating is not always the best choice. IP67 may be sufficient for outdoor installations exposed to rain or brief flooding, while a documented IP68 solution may suit submerged or difficult-to-access valves. Compare the initial cost with installation requirements, inspection frequency, seal replacement, maintenance access, downtime risk, expected service life, and spare-parts availability. Before purchasing, request product data, dimensional drawings, IP test documentation, tested depth and duration, approved mounting positions, cable-gland requirements, wiring diagrams, and maintenance instructions. Remember that corrosion resistance, hazardous-area certification, and electrical safety requirements must be evaluated separately from the IP rating.

Real-World Applications and Failures of IP67 and IP68 Electric Valve Actuators

Where IP67 Actuators Are Often Appropriate

IP67 actuators are commonly considered for valve installations exposed to rain, dust, splashing, or temporary flooding.

Examples include:

  • Above-ground water pipelines

  • Outdoor utility systems

  • Irrigation networks

  • Industrial valve stations

  • Drainage facilities

  • Dusty workshops

  • Temporarily flooded chambers

The actuator should be installed with compatible cable glands and in an approved orientation. Any unused openings must be sealed correctly.

Where IP68 May Be Required

IP68 may be more appropriate when immersion is expected as part of normal service rather than as a brief accident.

Possible applications include:

  • Permanently submerged valves

  • Dam and reservoir systems

  • Underground chambers with recurring flooding

  • Water-intake systems

  • Submerged irrigation equipment

  • Selected wastewater installations

  • Marine-related water-control systems

The purchase specification must define the actual depth, duration, fluid, operating state, and maintenance access.

Common Failures Caused by Incorrect Selection

Incorrect interpretation of IP ratings can lead to preventable failures.

  • Using IP67 for prolonged immersion: Exposure beyond the rated test condition may allow water to reach the motor or electrical components.

  • Assuming every IP68 actuator is identical: Different models may have different approved depths, durations, and installation requirements.

  • Ignoring cable entries: A correctly rated enclosure can still leak through unsuitable glands, loose connectors, or unsealed openings.

  • Operating underwater without confirmation: Shaft movement and pressure changes may affect seals that were tested only under stationary conditions.

  • Confusing immersion and washdown protection: An immersion rating does not automatically prove resistance to high-pressure or high-temperature cleaning.

  • Ignoring corrosion conditions: An IP rating does not indicate resistance to saltwater, chemicals, or corrosive atmospheres.

  • Opening the enclosure in the field: Incorrect reassembly, damaged gaskets, or trapped debris can reduce the original protection level.

Maintenance Practices That Preserve Ingress Protection

Regular inspection helps maintain the enclosure protection achieved during production and installation.

Maintenance teams should:

  • Inspect gaskets, O-rings, and shaft seals

  • Check cable glands and connectors

  • Confirm that covers remain correctly tightened

  • Examine the enclosure for corrosion or impact damage

  • Keep sealing surfaces clean

  • Replace hardened, cracked, or compressed seals

  • Follow approved cleaning methods

  • Record any enclosure opening or field repair

  • Conduct functional checks after flooding or immersion

Maintenance intervals should reflect the environment, operating frequency, and supplier instructions.

Tip: After severe flooding or exposure beyond the declared rating, inspect and test the actuator before returning it to normal service.

Installation and Maintenance Considerations for IP67 and IP68 Electric Valve Actuators

Best Practices for Mounting and Sealing

Install the actuator according to the approved mounting orientation and manufacturer instructions. Avoid positions that allow water to collect around covers, shaft interfaces, cable glands, or manual controls.

Mounting surfaces should be aligned and stable. Excessive mechanical stress can distort the actuator-valve connection and affect seals. Fasteners should be tightened to the specified torque rather than tightened by estimation.

Do not apply unapproved sealants to joints or openings. Some chemicals may damage gaskets, interfere with maintenance, or prevent correct enclosure assembly.

Protecting Cables and Electrical Connections

Cable entries are common ingress points. Cable glands, connectors, plugs, and conduits should match or exceed the required protection level when assembled.

During installation:

  • Use the specified cable diameter

  • Match glands to cable type and enclosure thread

  • Seal all unused entries with approved plugs

  • Avoid upward-facing cable routes where water can collect

  • Provide strain relief

  • Prevent sharp cable bends

  • Inspect connector seals before assembly

  • Follow the specified tightening method

The declared enclosure rating may not apply if alternative cable glands or connectors are installed without verification.

Inspection and Seal Replacement

Seals may degrade because of temperature cycling, UV exposure, chemical contact, vibration, aging, or repeated enclosure opening.

Routine inspections should look for:

  • Cracks or hardening

  • Flattened gaskets

  • Loose covers

  • Corroded sealing surfaces

  • Damaged cable glands

  • Condensation inside the enclosure

  • Water marks near terminals

  • Increased operating resistance

  • Irregular position feedback

Replacement seals should match the actuator specification. Similar-looking seals may differ in dimensions, hardness, temperature range, and chemical compatibility.

Avoiding Installation Errors

Common installation mistakes include:

  • Using non-rated cable glands

  • Leaving unused cable entries open

  • Installing damaged O-rings

  • Trapping wires across sealing surfaces

  • Overtightening or undertightening covers

  • Mounting the actuator in an unapproved position

  • Opening the enclosure in wet or dusty conditions

  • Failing to restore seals after maintenance

  • Directing pressure-cleaning jets at unsuitable interfaces

  • Assuming IP68 eliminates all maintenance requirements

A final installation inspection should verify the actuator, cable entries, covers, wiring, mounting position, and valve connection as one complete assembly.

Conclusion

IP67 and IP68 electric valve actuators provide the same dust-tight classification but differ in water-ingress protection. IP67 addresses temporary immersion under standardized conditions. IP68 applies to immersion conditions specifically declared for the product.

Industrial buyers should not choose solely by comparing the final digit. The decision must consider water depth, exposure duration, operating state, mounting orientation, cable entries, corrosion conditions, maintenance access, and supporting test documents.

Yangzhou Hengchun Electronics Co., Ltd. provides electric valve actuator solutions for industrial valve-control applications. Buyers can submit valve details, torque requirements, control signals, installation conditions, and required IP protection to confirm the appropriate actuator configuration.

FAQ

Q: What Is an Electric Valve Actuator, and Why Is Its IP Rating Important?

A: An electric valve actuator uses electrical power to open, close, or position a valve. Its IP rating describes the enclosure’s protection against solid objects and water ingress under defined test conditions.

Q: What Is the Main Difference Between IP67 and IP68 Electric Valve Actuators?

A: Both are dust-tight. IP67 covers temporary immersion under standardized conditions, while IP68 covers immersion under conditions declared by the manufacturer. The exact IP68 depth and duration must be confirmed.

Q: Is Every IP68 Electric Valve Actuator Suitable for Permanent Underwater Use?

A: No. IP68 does not automatically mean unlimited or permanent underwater operation. Buyers must verify the approved depth, duration, mounting position, operating state, and test documentation.

Q: Can an IP67 Electric Valve Actuator Operate While Submerged?

A: Not necessarily. IP67 confirms enclosure protection during its specified test, but it does not automatically verify powered valve operation or repeated movement underwater. Request application-specific confirmation.

Q: Is IP68 Always Better Than IP67?

A: IP68 provides a different level of immersion protection, but it is not always necessary. IP67 may be more suitable and economical for outdoor applications involving rain, splashing, and brief flooding.

Hengchun Actuator manufactures electric, pneumatic, electro-hydraulic & gas-over-oil valve actuators for oil & gas, power, and water industries. ISO certified, explosion-proof, smart control solutions.

Quick Links

Product Category

Contact Us

Add:  Ji'an N Rd, Hanjiang District, Yangzhou, Yangzhou, Jiangsu, China
Tel: +86-514-80826580
Mobile phone: +86-19952453579
Copyright © 2026 Yangzhou Hengchun Electronics Co., Ltd. All Rights Reserved. Sitemap Privacy Policy